Water Filters - FRF Series Specifications
Model FRF 50 Fully Automatic
Media Filter Vessel Piping and Valve
Part
Number: 919005 (if purchased w/o media)
System
Type: Polyglass Vessel with Top Mount TM III Valve
Pipe
Size: 1½” or 2” Grooved and NPT Galvanized Sch 40
Bypass: Unit will bypass hard water during
regeneration
Valve: Task Master III™ valve (707150-X)
Control:
ERCt demand (707201)
99-day electronic timer or remote actuated backwash
Mineral Tank:
13x52 Polyglass
(100046)
Distributor: Single point slotted distributor (1½”) 703006
Filter Area: 0.79 ft2
Dimensions (HtxDepthxWidth): 63” x 12”
x 21”
(add one foot to height for loading media)
Shipping Weight (less media): 190 lbs
Standard BW Rates High/Med/Low: 6, 8, 10
gpm
Model FRF 70 Fully Automatic
Media Filter Vessel Piping and Valve
Part
Number: 919007 (if purchased w/o media)
System
Type: Polyglass Vessel with Top Mount TM III Valve
Pipe
Size: 1½” or 2” Grooved and NPT Galvanized Sch 40
Bypass: Unit will bypass hard water during
regeneration
Valve: Task Master III™ valve (707150-X)
Control:
ERCt demand (707201)
99-day electronic timer or remote actuated backwash
Mineral Tank:
13x52 Polyglass
(100044)
Distributor: Single point slotted distributor (1½”) 703006
Filter Area: 0.92 ft2
Dimensions (HtxDepthxWidth): 63” x 13”
x 21”
(add one foot to height for loading media)
Shipping Weight (less media): 195 lbs
Standard BW Rates
High/Med/Low: 8, 10, 12 gpm
Model FRF 100 Fully Automatic
Media Filter Vessel Piping and Valve
Part
Number: 919010 (if purchased w/o media)
System
Type: Polyglass Vessel with Top Mount TM III Valve
Pipe
Size: 1½” or 2” Grooved and NPT Galvanized Sch 40
Bypass: Unit will bypass hard water during
regeneration
Valve: Task Master III™ valve (707150-X)
Control:
ERCt demand (707201)
99-day electronic timer or remote actuated backwash
Mineral Tank: 14x65
Polyglass (100017)
Distributor: Single point slotted distributor (1½”) 703006
Filter Area: 1.07 ft2
Dimensions (HtxDepthxWidth): 74” x 14”
x 21”
(add one foot to height for loading media)
Shipping Weight (less media): 200 lbs
Standard BW Rates
High/Med/Low: 15, 15, 10 gpm
Model FRF 120 Fully Automatic
Media Filter Vessel Piping and Valve
Part
Number: 919012 (if purchased w/o media)
System
Type: Polyglass Vessel with Top Mount TM III Valve
Pipe
Size: 1½” or 2” Grooved and NPT Galvanized Sch 40
Bypass: Unit will bypass hard water during
regeneration
Valve: Task Master III™ valve (707150-X)
Control:
ERCt demand (707201)
99-day electronic timer or remote actuated backwash
Mineral Tank: 16x65
Polyglass (100087)
Distributor: Single point slotted distributor (1½”) 703006
Filter Area: 1.4 ft2
Dimensions (HtxDepthxWidth): 74” x 16”
x 21”
(add one foot to height for loading media)
Shipping Weight (less media): 250 lbs
Standard BW Rates
High/Med/Low: 20, 15, 12 gpm
Model FRF 150 Fully Automatic
Media Filter Vessel Piping and Valve
Part
Number: 919015 (if purchased w/o media)
System
Type: Polyglass Vessel with Top Mount TM III Valve
Pipe
Size: 1½” or 2” Grooved and NPT Galvanized Sch 40
Bypass: Unit will bypass hard water during
regeneration
Valve: Task Master III™ valve (707150-X)
Control:
ERCt demand (707201)
99-day electronic timer or remote actuated backwash
Mineral Tank: 21x62
Polyglass (100190)
Distributor: Single point slotted distributor (1½”) 703006
Filter Area: 2.4 ft2
Dimensions (HtxDepthxWidth): 71” x 21”
x 22”
(add one foot to height for loading media)
Shipping Weight (less media): 335 lbs
Standard BW Rates
High/Med/Low: 35, 30, 20 gpm
Model FRF 240 Fully Automatic
Media Filter Vessel Piping and Valve
Part
Number: 919024 (if purchased w/o media)
System
Type: Polyglass Vessel with Top Mount TM III Valve
Pipe
Size: 1½” or 2” Grooved and NPT Galvanized Sch 40
Bypass: Unit will bypass hard water during
regeneration
Valve: Task Master III™ valve (707150-X)
Control:
ERCt demand (707201)
99-day electronic timer or remote actuated backwash
Mineral Tank: 24x72
Polyglass (100189)
Distributor: Single point slotted distributor (1½”) 703006
Filter Area: 3.14 ft2
Dimensions (HtxDepthxWidth): 81” x 24”
x 24”
(add one foot to height for loading media)
Shipping Weight (less media): 605 lbs
Standard BW Rates
High/Med/Low: 50, 35, 25 gpm
Model FRF 300 Fully Automatic
Media Filter Vessel Piping and Valve
Part
Number: 919030 (if purchased w/o media)
System
Type: Polyglass Vessel with Top Mount TM III Valve
Pipe
Size: 1½” or 2” Grooved and NPT Galvanized Sch 40
Bypass: Unit will bypass hard water during
regeneration
Valve: Task Master III™ valve (707150-X)
Control:
ERCt demand (707201)
99-day electronic timer or remote actuated backwash
Mineral Tank: 30x72
Polyglass (100187)
Distributor: Single point slotted distributor (1½”) 703006
Filter Area: 4.90 ft2
Dimensions (HtxDepthxWidth): 81” x 30”
x 30”
(add one foot to height for loading media)
Shipping Weight (less media): 1035 lbs
Standard BW Rates
High/Med/Low: 70, 60, 40 gpm
Model FRF 600 Fully Automatic
Media Filter Vessel Piping and Valve
Part
Number: 919060 (if purchased w/o media)
System
Type: Polyglass Vessel with Top Mount TM III Valve
Pipe
Size: 1½” or 2” Grooved and NPT Galvanized Sch 40
Bypass: Unit will bypass hard water during
regeneration
Valve: Task Master III™ valve (707150-X)
Control:
ERCt demand (707201)
99-day electronic timer or remote actuated backwash
Mineral Tank: 36x72
Polyglass (100187)
Distributor: Single point slotted distributor (1½”) 703006
Filter Area: 4.90 ft2
Dimensions (HtxDepthxWidth): 81” x 36”
x 36”
(add one foot to height for loading media)
Shipping Weight (less media): 1400 lbs
Standard BW Rates
High/Med/Low: --, --, 60 gpm (max BW rate is 70 gpm)
Notes:
Backwash Rates
|
H |
M |
L |
919005 |
FRF 50 |
12x52 FRP |
10 |
8 |
6 |
919007 |
FRF 70 |
13x54 FRP |
12 |
10 |
8 |
919010 |
FRF 100 |
14x65 FRP |
15 |
15 |
10 |
919012 |
FRF 120 |
16x65 FRP |
20 |
15 |
12 |
919015 |
FRF 150 |
21x62 FRP |
35 |
30 |
20 |
919024 |
FRF 240 |
24x72 FRP |
50 |
35 |
25 |
919030 |
FRF 300 |
30x72 FRP |
70 |
60 |
40 |
919045 |
FRF 600 |
36x72 FRP |
(1) |
(1) |
60 |
(1)
Maximum BW is 70 gpm. |
High –
Multimedia; Medium – Filter Sand and Green Sand; Low – Activated Carbon
and Filter AG. |
Dimensions:
Height is tank height plus
9” for valve.
Depth is equal to tank
diameter.
Width is determined by the
relationship between the top mounted valve and the vessel diameter. Valve sticks
out 12” from centerline on one side and 9” from the other. The minimum filter
width is 21”.
Applicable Media Packs:
Media Pack Part No. |
Model No. |
FRP Vessel Size |
Media Volume (ft3) |
Gravel (lbs) |
479X01 |
45 |
10x54 |
1 |
15 |
479X02 |
50 |
12x52 |
1 |
15 |
479X03 |
70 |
13x54 |
2 |
30 |
479X04 |
100 |
14x65 |
3 |
40 |
479X05 |
120 |
16x65 |
4 |
55 |
479X06 |
150 |
21x62 |
5 |
140 |
479X07 |
240 |
24x72 |
8 |
200 |
479X08 |
300 |
30x72 |
10 |
200 |
479X09 |
450 |
36x72 |
15 |
300 |
X |
|
Media Type |
0 |
|
Less
Media |
3 |
|
Neutralizing Media - Calcite and GMO |
4 |
|
Filter
AG |
5 |
|
Sand
(0.45 to 0.55 mm) |
6 |
|
Manganese Green Sand |
7 |
|
Activated Carbon |
8 |
|
Multi
media |
Mineral Tank Part Numbers:
Model No. |
Tank Size
|
Part No. |
50 |
12" x 52" |
100044 |
70 |
13” x 54” |
100046 |
100 |
14" x 65" |
100017 |
120 |
16" x 65" |
100087 |
150 |
21" x 62" |
100089 |
240 |
24" x 72" |
100187 |
300 |
30” x 72” |
100190 |
600 |
36” x 72” |
100189 |
900 |
42” x 72” |
100192 |
1200 |
48” x 72” |
|