Delivering Experience, Quality, and Service since 1934.
HOME - Water Softeners - BF Series Softeners
BROCHURE | SPECIFICATIONS | O&M MANUAL | PRICE LISTS | DRAWINGS | SKID MOUNTING
features Magnum IT - 1½ & 2” Valve – top mount ERCt Electronic Timer Polyglass Mineral Tanks Accumaticä Brine System. resin polystyrene 8% dvb cl single point ABS distributor Options Twin configuration Twin Alternating with ERCd Skid mounting 220V, 50Hz, 1Ø Operating Conditions Water pressure 25 to 100 psi Cold water operation 100°F maximum temperature BF Series Application Table Model1 240 300 450 600 Mineral Tank 24x72 30x72 36x72 36x72 Resin Volume (ft3) 8 10 15 20 Gravel (lbs) 200 250 300 300 Brine Tank 24x50 24x50 30x50 39x60 Salt Storage (lbs) 580 580 900 2,040 Brine Valve (in) ⅜ ⅜ ½ ½ Capacity (Kgr) 245 293 432 594 Salt per Regen (lbs) 106 106 145 244 Continuous Flow2 (gpm) 61 67 69 71 Peak Flow3 (gpm) 82 89 91 94 Backwash Rate4 (gpm) 15 25 35 35 Height5 (in) 78 82 96 96 Depth (in) 24 30 36 36 Width (in) 54 60 72 72 Twin Width6 (in) 84 96 114 114 Single Weight (lbs) 915 1085 1385 1645 Twin Weight 6 (lbs) 1355 2090 2600 2825
features
Magnum IT - 1½ & 2” Valve – top mount ERCt Electronic Timer Polyglass Mineral Tanks Accumaticä Brine System. resin polystyrene 8% dvb cl single point ABS distributor
Options
Twin configuration Twin Alternating with ERCd Skid mounting 220V, 50Hz, 1Ø
Operating Conditions
Water pressure 25 to 100 psi Cold water operation 100°F maximum temperature
BF Series Application Table
Model1
240
300
450
600
Mineral Tank
24x72
30x72
36x72
Resin Volume (ft3)
8
10
15
20
Gravel (lbs)
200
250
Brine Tank
24x50
30x50
39x60
Salt Storage (lbs)
580
900
2,040
Brine Valve (in)
⅜
½
Capacity (Kgr)
245
293
432
594
Salt per Regen (lbs)
106
145
244
Continuous Flow2 (gpm)
61
67
69
71
Peak Flow3 (gpm)
82
89
91
94
Backwash Rate4 (gpm)
25
35
Height5 (in)
78
96
Depth (in)
24
30
36
Width (in)
54
60
72
Twin Width6 (in)
84
114
Single Weight (lbs)
915
1085
1385
1645
Twin Weight 6 (lbs)
1355
2090
2600
2825